Flow Dividers
Canadian Shield Consultants offers a complete line of decentralized wastewater treatment products and services. The PFS-200 to PFS-1000 pressurized flow dividers are suitable for any septic installation requiring division of effluent flow.
PFS-200 to PFS-1000 Pressurized Flow Dividers
Premier Tech Aqua’s PFS-200 to PFS-1000 Pressurized Flow Dividers divide a pumped effluent flow into equal portions, according to installation needs. They enable cluster installation of several Ecoflo® ST-650 Biofilters in high wastewater flow applications.
Operation Principle
The unit divides the effluent flow using pressure generated by the pump and then distributes the effluent to the treatment units through gravity flow pipes. This way, the length of the piping systems is irrelevant. All liquid must be pumped out of the enclosure before the next dosing. If the installation design does not enable this, then measures must be taken to protect the system from freezing.
Advantages
- Division of effluent flow into equal portions;
- Low-cost solution;
- Quick and easy installation;
- Easy access to all components;
- Virtually maintenance free.
Features
- PVC and polyethylene construction;
- Operation pressure: 7 kPa (1 psi) minimum and 28 kPa (4 psi) maximum.
- 2 and 3 outlets pressurized flow dividers
- Discrepancy of less than 5%;
- Fits flexible inlet pipe, 38 mm (1.5″) inside diameter;
- PVC outlet pipe, 100 mm (4″) – dr 35, 108 mm (4.25″) outside diameter.
- 4 to 10 outlets pressurized flow dividers
- Flow discrepancy of less than 8%;
- Contained in 600 mm (24″) polyethylene casing;
- Fits flexible inlet pipe, 51 mm (2″) inside diameter;
- PVC outlet pipe, 100 mm (4″) – DR 35 outside diameter.
Operation
Installation requires nothing more than connecting the outlet end of the pumping station to the inlet of the pressurized flow divider;
Gravity outlets are connected to 100 mm (4″) PVC pipes that are connected directly to Ecoflo® ST-650 Biofilters or any soil absorption system;
The casing lid must be accessible at all times to enable annual system inspection and maintenance (or as needed).
Client Testimonials
"I would be happy to recommend Canadian Shield Consultants Agency and I would hire them again if the need arose."
Madeleine Nadon - Homeowner -
"In my opinion, the true test of a good business is whether or not you would use their services again. In the case of Canadian Shield Consultants Agency, Gerry and his crew, the answer is we still are using their services and we consider them our "Go To" guys!"
Wayne Johnson - Manager - YMCA-YWCA of Winnipeg
"Throughout the entire month long project CSCA did not veer from the original goal and made MRWs time in St. Charles a positive experience."
John Sikorski - Engineering Technologist - M.R. Wright and Associates Co. Ltd.
"We are very thankful for all that Gerry and his company have done for us up to now...their expertise and assistance has facilitated the process of purchasing a good quality septic system that meets the Ministry of Environment's standards."
Ms. Réjeanne de Bois - Owner - Minakwa Lodge and Trailer Park
"We were very impressed with your heavy duty machinery, and realized we were not dealing with a start-up company. All workmen on the site knew their jobs and performed all labour with such care and skill. I must add a personal comment that the workers were very amicable, answered all our questions and did not mind the interruptions when we asked for clarification as to what they were doing"
Jean McConnell - Former Manager of Recreational Arenas and Swimming Pools - City of Greater Sudbury